ENVISION'S LINE OF ECO-AWARE PRODUCTS ARE DESIGNED
TO HELP YOU MEET YOUR EMISSION REDUCTION GOALS
Flame & Detonation Arrestors
Flame & Detonation Arrestors are key components commonly used in the design of your flare system to prevent the propagation of flame fronts into your piping systems. We offer both Deflagrations (Flame) Arrestors to be used near the source, and Detonation Arrestors which are designed to be used in piping systems.
PREVENT THE PROPOGATION OF FLAME FRONTS ON YOUR SYSTEMS
FLAME ARRESTORS
DETONATION ARRESTORS
INLINE DETONATION ARRESTORS
INLINE DETONATION ARRESTOR
-
Operating Temperature @ Pressure - KFD / DN 15 ~ DN 300 +60°C/140°F @ 1.1 bar abs
-
Made from reliable materials (nodular iron, cast steel, SS304, SS316, SS316L with various trims)
-
A range of sizes available to fit your existing equipment (DN 15 ~ DN 300 with ANSI 150lb flanges)
-
Flame cell: NEC group D or IEC IIA Gases (Other gas groups all available as extras)
-
Optimum/Optional Design & Arrangements - Stem Jacket type, Steam Tracing type
KSPC - KSFD Inline Detonation Flame Arrestor
INLINE DETONATION ARRESTOR
-
Operating Temperature @ Pressure - KSFD / DN 25 ~ DN 150 +90°C/194°F @ 1.2 bar abs; KSFD / DN 200 ~ DN 400 +90°C/194°F @ 1.1 bar abs
-
Made from reliable materials (cast steel, SS304, SS316, SS316L with various trims)
-
A range of sizes available to fit your existing equipment (DN 25 ~ DN 400 with ANSI 150lb flanges)
-
Flame cell: NEC group D or IEC IIA Gases (Other gas groups all available as extras)
-
Optimum/Optional Design & Arrangements - Stem Jacket type, Steam Tracing type
KSPC - KSFC Inline Detonation Flame Arrestor
INLINE DETONATION ARRESTOR
-
Operating Temperature @ Pressure - KSFLD / DN 50 ~ DN 300 +60°C/140°F @ 1.1 bar abs
-
Made from reliable materials (nodular iron, cast steel, SS304, SS316, SS316L with various trims)
-
A range of sizes available to fit your existing equipment (DN 50 ~ DN 300 with ANSI 150lb flanges)
-
Flame cell: NEC group D or IEC IIA Gases (Other gas groups all available as extras)
-
Optimum/Optional Design & Arrangements - Stem Jacket type, Steam Tracing type
KSPC - KSFLD Inline Detonation Flame Arrestor
DEFLAGRATION FLAME ARRESTORS
DEFLAGRATION FLAME ARRESTOR
-
Operating Temperature @ Pressure - KSFE / DN 50 ~ DN 300 +90°C/194°F @ 1.1 bar abs
-
Made from reliable materials (aluminum, nodular iron, cast steel, SS304, SS316, SS316L with various trims)
-
A range of sizes available to fit your existing equipment (DN 50 ~ DN 300 with ANSI 150lb flanges)
-
Flame cell: NEC group D or IEC IIA Gases (other gas groups all available as extras)
-
Optimum/Optional Design & Arrangements - Stem Jacket type, Steam Tracing type
KSPC - KSFE Deflagration Flame Arrestor
DEFLAGRATION FLAME ARRESTOR
-
Operating Temperature @ Pressure - KSFH / DN 50 ~ DN 350 +60°C/140°F @ 1.1 bar abs
-
Made from reliable materials (aluminum, nodular iron, cast steel, SS304, SS316, SS316L with various trims)
-
A range of sizes available to fit your existing equipment(DN 50 ~ DN 300 with ANSI 150lb flanges)
-
Flame cell: NEC group D or IEC IIA Gases (other gas groups all available as extras)
-
Optimum/Optional Design & Arrangements - Stem Jacket type, Steam Tracing type
KSPC - KSFH Deflagration Flame Arrestor
DEFLAGRATION FLAME ARRESTOR
-
Operating Temperature @ Pressure - KSFI / DN 15 ~ DN 600 +60°C/140°F @ 1.1 bar abs
-
Made from reliable materials (aluminum, nodular iron, cast steel, SS304, SS316, SS316L with various trims)
-
A range of sizes available to fit your existing equipment (DN 15 ~ DN 600 with ANSI 150lb flanges)
-
Flame cell: NEC group D or IEC IIA Gases (other gas groups all available as extras)
KSPC - KSFI Deflagration Flame Arrestor
DEFLAGRATION FLAME ARRESTOR
-
Operating Temperature @ Pressure - KSFL / DN 50 ~ DN 300 +60°C/140°F @ 1.1 bar abs
-
Made from reliable materials (aluminum, nodular iron, cast steel, SS304, SS316, SS316L with various trims)
-
A range of sizes available to fit your existing equipment (DN 50 ~ DN 300 with ANSI 150lb flanges)
-
Flame cell: NEC group D or IEC IIA Gases (other gas groups all available as extras)
-
Optimum/Optional Design & Arrangements - Stem Jacket type, Steam Tracing type